<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>RAID | 3Aデータ復旧サービス</title>
	<atom:link href="https://3adata.jp/tag/raid/feed" rel="self" type="application/rss+xml" />
	<link>https://3adata.jp</link>
	<description>HDDのデータが見れない・認識しない等でお困りの方は大阪・京都・兵庫で最安値を目指す復旧・復元業者、安心安全安価データ復旧サービスへ</description>
	<lastBuildDate>Thu, 28 May 2026 10:19:55 +0000</lastBuildDate>
	<language>ja</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://3adata.jp/wp-content/uploads/12241577_492276204267747_893265889683158757_n-150x150.png</url>
	<title>RAID | 3Aデータ復旧サービス</title>
	<link>https://3adata.jp</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NASでよくあるトラブルとエラーメッセージ一覧｜原因と対処法を解説</title>
		<link>https://3adata.jp/blog/summary-of-nas-troubleshooting-causes</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Wed, 27 May 2026 08:21:37 +0000</pubDate>
				<category><![CDATA[3Aデータ復旧スタッフブログ]]></category>
		<category><![CDATA[NAS]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[トラブル]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=16712</guid>

					<description><![CDATA[NAS（ネットワークHDD）を使用していると、「RAID degraded」「Volume crashed」「Disk failure」などのエラーが表示されることがあります。 NASは複数のHDDを組み合わせて動作して [&#8230;]]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-cocoon-blocks-icon-box common-icon-box block-box information-box">
<p><strong>まず確認：「故障HDDをむやみに抜かない」「RAIDリビルドを繰り返さない」「初期化やフォーマットを安易に行わない」</strong>事が大切です。</p>
</div>



<p>NAS（ネットワークHDD）を使用していると、<br><strong><span class="marker-under-blue">「RAID degraded」「Volume crashed」「Disk failure」</span></strong>などのエラーが表示されることがあります。</p>



<p>NASは複数のHDDを組み合わせて動作しているため、 通常の外付けHDDより構造が複雑で、誤った対応をすると<strong>RAID崩壊やデータ消失につながる可能性があります。</strong></p>



<p>この記事では、NASで発生しやすいトラブルやエラーメッセージ、 正しい対処方法と絶対にやってはいけないNG行動を分かりやすく解説します。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading">NASのトラブルは大きく4種類に分かれる</h2>



<h3 class="wp-block-heading">RAID障害</h3>



<p>NAS特有で最も多いトラブルです。 RAID情報が破損すると、複数HDDが正常でもデータにアクセスできなくなることがあります。</p>



<ul class="wp-block-list">
<li>RAID degraded</li>



<li>RAID crashed</li>



<li>Rebuild failed</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">HDD故障・物理障害</h3>



<p>NAS内部のHDDが劣化・故障している状態です。 24時間運用されることが多く、通常のHDDより劣化が早いケースもあります。</p>



<ul class="wp-block-list">
<li>S.M.A.R.T error</li>



<li>Disk failure</li>



<li>Bad sector detected</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">ファイルシステム・ボリューム異常</h3>



<p>NAS内部のデータ構造が壊れている状態です。 RAID異常と同時に発生するケースも少なくありません。</p>



<ul class="wp-block-list">
<li>Volume crashed</li>



<li>ファイルシステムエラー</li>



<li>ボリュームがマウントされていません</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">ネットワーク・接続異常</h3>



<p>NAS本体ではなく、接続環境に問題があるケースです。</p>



<ul class="wp-block-list">
<li>NASが見つからない</li>



<li>アクセス拒否</li>



<li>共有フォルダにアクセスできない</li>
</ul>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">NASトラブル発生時の判断フロー</h2>



<p>HDDやRAIDでトラブルが発生した場合は確認してみてください。</p>



<pre class="wp-block-preformatted">NASエラー発生
        │
   ┌────┼──────────────┐
   │    │              │
接続確認     RAID確認         HDD確認
   │    │              │
LAN確認       degraded表示      異音・SMART
IP確認        crashed表示       failure表示
   │    │              │
   │    │              │
軽度なら復旧    操作停止         通電最小限
</pre>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading">NASでよくあるエラー危険度一覧</h2>



<h3 class="wp-block-heading">■ 危険度の基準</h3>



<ul class="wp-block-list">
<li>★☆☆☆☆ = 軽度（自力対応可能）</li>



<li>★★★☆☆ = 中度（慎重対応）</li>



<li>★★★★★ = 重度（即使用停止レベル）</li>
</ul>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><th>エラー内容</th><th>危険度</th><th>主な原因</th><th>推奨対応</th></tr><tr><td>アクセス拒否</td><td>★★☆☆☆</td><td>権限設定</td><td>設定確認</td></tr><tr><td>NASが見つからない</td><td>★★★☆☆</td><td>ネットワーク異常</td><td>LAN・IP確認</td></tr><tr><td>RAID degraded</td><td>★★★★☆</td><td>HDD故障</td><td>慎重にHDD確認</td></tr><tr><td>S.M.A.R.T error</td><td>★★★★☆</td><td>HDD劣化</td><td>バックアップ優先</td></tr><tr><td>Bad sector detected</td><td>★★★★☆</td><td>不良セクタ</td><td>状態確認・慎重対応</td></tr><tr><td>Volume crashed</td><td><strong>★★★★★</strong></td><td>RAID崩壊</td><td>操作停止</td></tr><tr><td>RAID crashed</td><td><strong>★★★★★</strong></td><td>RAID障害</td><td>即慎重対応</td></tr><tr><td>Disk failure</td><td><strong>★★★★★</strong></td><td>HDD故障</td><td>通電最小限</td></tr><tr><td>Rebuild failed</td><td><strong>★★★★★</strong></td><td>RAID復旧失敗</td><td>リビルド停止</td></tr></tbody></table></figure>



<div class="wp-block-cocoon-blocks-icon-box common-icon-box block-box information-box">
<p><strong>ポイント：</strong>危険度が高い場合は物理障害が発生している可能性がありますので、<br>通電を控え、適切な対応がデータの救出に繋がります。</p>
</div>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">エラー別の原因</h2>



<h3 class="wp-block-heading">アクセス拒否の原因</h3>



<p><strong><span class="bold-red">危険度：★★☆☆☆（低〜中）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>NASのユーザー権限設定ミス</li>



<li>共有フォルダのアクセス制限</li>



<li>Active Directory・LDAP連携異常</li>



<li>ファイルシステムの軽度破損</li>



<li>RAIDやボリューム異常による一時的なアクセス不能</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>権限設定だけでなく、内部障害が原因の場合もある</li>



<li>複数ユーザーで同時に発生している場合はNAS本体異常の可能性がある</li>



<li>共有フォルダ設定を誤ると別データにも影響する場合がある</li>



<li>安易な初期化や共有設定変更は避けた方が安全</li>



<li>RAID異常を伴っている場合は状態悪化に注意が必要</li>
</ul>



<p></p>



<h3 class="wp-block-heading">NASが見つからないとなる場合の原因</h3>



<p><strong><span class="bold-red">危険度：★★★☆☆（中）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>LANケーブルの接触不良・断線</li>



<li>ルーターやスイッチングハブの不具合</li>



<li>NASのIPアドレス変更・競合</li>



<li>NAS本体のフリーズや起動異常</li>



<li>RAID異常やHDD故障による起動失敗</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>単なるネットワーク障害だけでなく、内部故障が原因の場合もある</li>



<li>再起動を繰り返すと状態悪化につながるケースがある</li>



<li>RAID異常が発生している場合、通電継続で劣化が進行する可能性がある</li>



<li>NAS初期化やRAID再構築は安易に行わない</li>



<li>異音やビープ音がある場合は物理障害の可能性が高い</li>
</ul>



<p></p>



<h3 class="wp-block-heading">RAID degradedの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★☆（高）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>NAS内部HDDの1台故障</li>



<li>HDDの劣化・不良セクタ増加</li>



<li>RAID同期中のエラー</li>



<li>突然の電源断や強制終了</li>



<li>HDDの接触不良や接続異常</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>RAID degradedは「まだ動いているが危険な状態」を意味する</li>



<li>この状態で別HDDが故障するとRAID崩壊につながる可能性がある</li>



<li>安易なリビルドは状態悪化につながる場合がある</li>



<li>故障HDDを順番を変えて抜くとRAID情報が破損することがある</li>



<li>長時間の通電で劣化が進行するケースもある</li>
</ul>



<p></p>



<h3 class="wp-block-heading">S.M.A.R.T errorの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★☆（高）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>NAS内部HDDの劣化・寿命</li>



<li>不良セクタの増加</li>



<li>読み書きエラーの蓄積</li>



<li>長時間運用によるHDD負荷</li>



<li>高温環境や振動によるダメージ</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>S.M.A.R.T errorはHDD故障の予兆として表示されることが多い</li>



<li>現在動作していても突然認識不能になる場合がある</li>



<li>RAID構成でも複数台故障につながるケースがある</li>



<li>リビルド中に別HDDが故障することも少なくない</li>



<li>通電を続けるほど状態が悪化する場合がある</li>
</ul>



<p></p>



<h3 class="wp-block-heading">Bad sector detectedの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★☆（高）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>NAS内部HDDの不良セクタ発生</li>



<li>HDDの経年劣化・寿命</li>



<li>長時間稼働によるディスク損傷</li>



<li>強制終了や突然の電源断</li>



<li>高温環境や振動による物理ダメージ</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>Bad sector detectedはHDD表面に読み取り不能領域が発生している状態</li>



<li>不良セクタは徐々に増加するケースが多い</li>



<li>RAID構成でも別HDDへ負荷が集中する場合がある</li>



<li>安易なリビルドや長時間運用で状態悪化につながることがある</li>



<li>放置するとRAID崩壊やVolume crashedへ進行する可能性がある</li>
</ul>



<p></p>



<h3 class="wp-block-heading">Volume crashedの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★★（最も危険）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>RAID情報の破損</li>



<li>複数HDDの同時障害</li>



<li>ファイルシステム（EXT4・Btrfs）の破損</li>



<li>リビルド失敗</li>



<li>突然の電源断や強制終了</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>Volume crashedはNAS内部ボリュームが正常に読み込めない状態</li>



<li>RAID構成が壊れている可能性が高い</li>



<li>安易なリビルドや初期化で復旧難易度が大きく上がる場合がある</li>



<li>故障HDDを順番を変えて抜くとRAID情報が破損することがある</li>



<li>通電を続けることで状態悪化につながるケースもある</li>
</ul>



<p></p>



<h3 class="wp-block-heading">RAID crashedの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★★（最も危険）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>複数HDDの同時故障</li>



<li>RAID情報（メタデータ）の破損</li>



<li>リビルド失敗</li>



<li>故障HDD交換時の順番ミス</li>



<li>突然の電源断・強制終了</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>RAID crashedはRAID構成が正常に維持できなくなっている状態</li>



<li>HDD自体が正常でも、RAID情報破損でアクセス不能になる場合がある</li>



<li>安易な初期化やRAID再構築で復旧難易度が大幅に上がることがある</li>



<li>故障HDDを順番を変えて抜くと状態悪化につながる可能性が高い</li>



<li>リビルドを繰り返すことで別HDDが故障するケースも少なくない</li>
</ul>



<p></p>



<h3 class="wp-block-heading">Disk failureの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★★（最も危険）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>NAS内部HDDの物理故障</li>



<li>HDDの寿命・経年劣化</li>



<li>不良セクタの増加</li>



<li>モーター・磁気ヘッド異常</li>



<li>高温環境や長時間稼働によるダメージ</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>Disk failureはHDDが正常動作できない状態を示している</li>



<li>RAID構成でも別HDDへ負荷が集中する場合がある</li>



<li>通電を続けることで状態悪化につながるケースがある</li>



<li>リビルドを安易に行うと別HDDが故障する可能性がある</li>



<li>異音（カチカチ音・ビープ音）が出ている場合は重度障害の可能性が高い</li>
</ul>



<p></p>



<h3 class="wp-block-heading">Rebuild failedの原因</h3>



<p><strong><span class="bold-red">危険度：★★★★★（最も危険）</span></strong></p>



<h4 class="wp-block-heading">原因</h4>



<ul class="wp-block-list">
<li>リビルド中に別HDDが故障した</li>



<li>HDD劣化・不良セクタの増加</li>



<li>RAID情報の破損</li>



<li>交換HDDの容量・仕様不一致</li>



<li>リビルド中の電源断や強制終了</li>
</ul>



<h4 class="wp-block-heading">注意点</h4>



<ul class="wp-block-list">
<li>Rebuild failedはRAID復旧処理が正常に完了できなかった状態</li>



<li>別HDDにも劣化が進行しているケースが多い</li>



<li>リビルドの再試行で状態悪化につながる場合がある</li>



<li>安易なHDD交換や順番変更はRAID情報破損の原因になる</li>



<li>通電を続けることで完全なRAID崩壊へ進行するケースもある</li>
</ul>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">NASで絶対にやってはいけないNG行動</h2>



<p>NASでエラーが発生した場合、焦って操作を続けるとRAID構成やHDDの状態が悪化し、復旧できたはずのデータが失われる可能性があります。 特に以下の行動は避けてください。</p>



<h3 class="wp-block-heading">故障HDDを順番を変えて抜く</h3>



<p><strong>NG理由：</strong>NASのRAID構成では、HDDの接続順や構成情報が重要です。 故障したと思われるHDDを自己判断で抜いたり、別のスロットに差し替えたりすると、RAID情報が正しく認識されなくなる可能性があります。</p>



<p>特に複数台構成のNASでは、HDDの順番が変わることでRAID構成が崩れ、データにアクセスできなくなるケースがあります。</p>



<p><strong>故障HDDを抜く場合は、管理画面で対象ディスクを確認し、順番を記録してから慎重に対応してください。</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">RAIDリビルドを何度も繰り返す</h3>



<p><strong>NG理由：</strong>RAIDリビルドは、残っているHDDから大量のデータを読み出して再構築する作業です。 そのため、劣化したHDDに大きな負荷がかかります。</p>



<p>リビルド中に別のHDDが故障すると、RAID全体が崩壊する可能性があります。 一度失敗したリビルドを何度も繰り返すと、不良セクタの拡大や別HDDの故障につながることがあります。</p>



<p><strong>Rebuild failedが出ている場合は、再実行よりも状態確認を優先してください。</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">初期化・フォーマットを実行する</h3>



<p><strong>NG理由：</strong>NASの管理画面で「初期化」「フォーマット」「ボリューム作成」などを実行すると、RAID情報やファイルシステム情報が上書きされる可能性があります。</p>



<p>データそのものが残っていても、管理情報が書き換わることで復旧難易度が大幅に上がる場合があります。</p>



<p><strong>「ボリュームが壊れています」「マウントできません」と表示されても、初期化やフォーマットは実行しないでください。</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">故障状態で通電を続ける</h3>



<p><strong>NG理由：</strong>異音、S.M.A.R.T error、Bad sector detected、Disk failureなどが出ている状態で通電を続けると、HDDの劣化が進行する可能性があります。</p>



<p>NASは24時間稼働することが多いため、故障状態のまま放置すると不良セクタが増えたり、別HDDにも負荷がかかったりすることがあります。</p>



<p><strong>異音や物理障害の疑いがある場合は、無理に稼働を続けず、通電を最小限にしてください。</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">RAIDだから安全と思い込む</h3>



<p><strong>NG理由：</strong>RAIDはHDD故障時の可用性を高める仕組みであり、バックアップではありません。 RAID構成でも、複数HDDの同時故障、誤削除、ファイルシステム破損、リビルド失敗などでデータにアクセスできなくなることがあります。</p>



<p>「RAIDだから大丈夫」と思ってバックアップを取っていない場合、障害発生時に大きな被害につながる可能性があります。</p>



<p><strong>NASに重要データを保存している場合は、別媒体やクラウドへのバックアップも必ず検討してください。</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p><strong>重要：</strong>NASのトラブルは、1台のHDD故障だけでなく、RAID情報・ボリューム・ファイルシステムまで影響することがあります。 自己判断でのリビルド、初期化、HDD交換を行う前に、まずは状態確認とバックアップを優先してください。</p>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">対処方法</h2>



<h3 class="wp-block-heading">アクセス拒否になる場合の対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li>NAS管理画面でユーザー権限を確認する</li>



<li>共有フォルダのアクセス設定を見直す</li>



<li>別ユーザー・別PCでアクセス確認を行う</li>



<li>RAID状態やボリューム異常がないか確認する</li>



<li>アクセスできる場合は重要データをバックアップする</li>



<li>改善しない場合は専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>アクセス拒否は単なる権限設定だけでなく、 RAID異常やファイルシステム障害が原因で発生している場合もあります。 特に突然アクセスできなくなった場合は、慎重な対応が重要です。</p>



<h3 class="wp-block-heading">NASが見つからないとなる場合の対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li>LANケーブル・ルーター・ハブを確認する</li>



<li>別のPCからアクセス確認を行う</li>



<li>NAS管理ツールでIPアドレスを確認する</li>



<li>Ping疎通確認を行う</li>



<li>NAS本体のランプ状態やビープ音を確認する</li>



<li>アクセスできた場合は重要データをバックアップする</li>



<li>改善しない場合は専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>NASが見つからない場合でも、 単なるネットワーク障害だけでなく、RAID異常やHDD故障が進行しているケースがあります。 安易な初期化やリビルドを行わず、慎重に状態を確認してください。</p>



<h3 class="wp-block-heading">RAID degradedの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li>まずは重要データのバックアップを最優先する</li>



<li>NAS管理画面で故障HDDを確認する</li>



<li>異音やSMART異常がないか確認する</li>



<li>故障HDD交換はRAID構成を確認した上で慎重に行う</li>



<li>リビルドは状態確認後に実施する</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>RAID degradedは「まだ読めるから安全」という状態ではありません。 1台故障した状態で動作を継続しているケースが多く、無理な操作を行うとRAID崩壊につながる可能性があります。</p>



<h3 class="wp-block-heading">S.M.A.R.T errorの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li>まずは重要データのバックアップを最優先する</li>



<li>NAS管理画面で異常HDDを確認する</li>



<li>HDD温度や異音の有無を確認する</li>



<li>RAID状態を確認し、無理なリビルドは避ける</li>



<li>異常HDD交換はRAID構成を確認した上で慎重に実施する</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>S.M.A.R.T errorは「故障寸前」を示す警告であるケースが少なくありません。 まだアクセスできる間にバックアップを行い、無理な運用継続は避けることが重要です。</p>



<h3 class="wp-block-heading">Bad sector detectedの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li>まずは重要データのバックアップを最優先する</li>



<li>NAS管理画面で不良セクタ数を確認する</li>



<li>S.M.A.R.T情報を確認する</li>



<li>異音や動作遅延がないか確認する</li>



<li>異常HDD交換はRAID構成を確認した上で慎重に実施する</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>Bad sector detectedはHDD劣化が進行しているサインです。 現在アクセスできていても、突然認識不能やRAID異常へ進行するケースがあるため、早めのバックアップが重要です。</p>



<h3 class="wp-block-heading">Volume crashedの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li><strong>まずは不用意な操作を停止する</strong></li>



<li>NAS管理画面でRAID状態・故障HDDを確認する</li>



<li>異音やSMARTエラーがないか確認する</li>



<li>リビルドや初期化は慎重に判断する</li>



<li>アクセス可能な場合は重要データを最優先でバックアップする</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>Volume crashedはRAID崩壊やファイルシステム障害が進行している可能性が高い状態です。 誤った操作によって複数HDDの情報が同時に破損するケースもあるため、慎重な対応が必要です。</p>



<h3 class="wp-block-heading">RAID crashedの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li><strong>まずは不用意な操作を停止する</strong></li>



<li>NAS管理画面でRAID状態を確認する</li>



<li>異音・SMARTエラー・故障HDDを確認する</li>



<li>HDDの抜き差しや順番変更は行わない</li>



<li>リビルドや初期化は慎重に判断する</li>



<li>アクセス可能な場合は重要データを最優先でバックアップする</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>RAID crashedはNAS障害の中でも特に深刻な状態です。 誤った操作によって複数HDDの情報が同時に破損し、復旧難易度が大きく上がるケースもあるため、慎重な対応が必要です。</p>



<h3 class="wp-block-heading">Disk failureの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li><strong>まずは重要データのバックアップを最優先する</strong></li>



<li>NAS管理画面で故障HDDを確認する</li>



<li>異音・SMARTエラー・不良セクタを確認する</li>



<li>不要な再起動やリビルドを繰り返さない</li>



<li>HDD交換はRAID構成を確認した上で慎重に実施する</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>Disk failureはHDDが故障している可能性が非常に高い状態です。 現在アクセスできていても突然RAID崩壊へ進行するケースがあるため、早めのバックアップと慎重な対応が重要です。</p>



<h3 class="wp-block-heading">Rebuild failedの対処方法</h3>



<h4 class="wp-block-heading">対処方法</h4>



<ul class="wp-block-list">
<li><strong>まずはリビルド作業を中断し、状態確認を行う</strong></li>



<li>NAS管理画面で故障HDD・SMART状態を確認する</li>



<li>異音や不良セクタがないか確認する</li>



<li>HDDの抜き差しや順番変更を行わない</li>



<li>アクセス可能な場合は重要データを最優先でバックアップする</li>



<li>重要データは専門業者へ相談</li>
</ul>



<p><strong>重要：</strong>Rebuild failedは、RAID構成全体が不安定になっている可能性が高い状態です。 無理にリビルドを繰り返すことで、複数HDDが同時に故障し、復旧難易度が大きく上がるケースもあります。</p>



<h2 class="wp-block-heading">NASデータ復旧の成功事例</h2>



<h3 class="wp-block-heading">Synology DiskStationの復旧事例</h3>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td class="has-text-align-center" data-align="center"><strong>機器</strong></td><td>Synology DiskStation</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>症状</strong></td><td>「RAID degraded」と表示されアクセス不安定</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>診断</strong></td><td>DD1台の物理障害・不良セクタ発生</td></tr></tbody></table></figure>



<p>突然NASへのアクセス速度が低下し、管理画面上に「RAID degraded」が表示される状態でした。 お客様側でリビルドを実施する前にご相談いただいたため、状態悪化を防いだまま対応を開始しました。<br>専用機器でHDD状態を確認したところ、1台に不良セクタが発生しており、RAID情報にも不整合が発生していました。RAID構成を解析し、破損したボリューム情報を修復した結果、 保存されていた業務データ・共有フォルダの復旧に成功しました。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">QNAP NASの復旧事例</h3>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td class="has-text-align-center" data-align="center"><strong>機器</strong></td><td>QNAP NAS</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>症状</strong></td><td>「Volume crashed」と表示され共有フォルダへアクセス不可</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>診断</strong></td><td>RAID情報破損・複数HDD劣化</td></tr></tbody></table></figure>



<p>突然共有フォルダへアクセスできなくなり、NAS管理画面上で「Volume crashed」が表示される状態でした。<br>お客様が初期化を行わず、そのままの状態でご相談いただいたため、RAID情報を保持したまま解析を実施。<br>複数HDDに劣化が見られましたが、RAID構成を再解析し、 業務データ・写真・動画ファイルを含む大部分のデータ復旧に成功しました。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">Buffalo TeraStationの復旧事例</h3>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td class="has-text-align-center" data-align="center"><strong>機器</strong></td><td>Buffalo TeraStation</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>症状</strong></td><td>リビルド途中で「Rebuild failed」表示</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>診断</strong></td><td>別HDDにも不良セクタ発生</td></tr></tbody></table></figure>



<p>故障HDD交換後にリビルドを実施したところ、途中で「Rebuild failed」が表示されアクセス不能になったケースです。<br>確認したところ、交換前から別HDDにも劣化が進行しており、リビルド負荷によって状態が悪化していました。<br>専用環境でRAID解析と不良領域の読み出しを行い、 重要業務データの復旧に成功しました。</p>



<div class="wp-block-cocoon-blocks-icon-box common-icon-box block-box information-box">
<p><strong>ポイント：</strong>NAS障害では、初期化・リビルド再実行・HDD順番変更などによって状態が悪化するケースがあります。 特にRAID degraded・Volume crashed・Rebuild failedが表示されている場合は慎重な対応が重要です。</p>
</div>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">よくある質問（FAQ）</h2>



<h3 class="wp-block-heading">RAIDを組んでいればデータは安全ですか？</h3>



<p>RAIDはHDD故障時の可用性を高める仕組みですが、完全なバックアップではありません。 複数HDDの同時故障やRAID崩壊、誤操作などでデータにアクセスできなくなるケースもあります。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">NASが突然見つからなくなりました。どうすればいいですか？</h3>



<p>LANケーブルやルーターなど接続環境の問題だけでなく、NAS本体やHDD異常が原因の場合もあります。 まずはネットワーク環境を確認し、異音やエラー表示がないかも確認してください。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">RAID degradedはすぐに危険な状態ですか？</h3>



<p>1台のHDD故障などでRAID構成が不完全になっている状態です。 このまま運用を続けると、別HDD故障時にRAID崩壊につながる可能性があります。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">Rebuild failedが表示された場合はどうすればいいですか？</h3>



<p>リビルド失敗は、別HDDにも異常が発生している可能性があります。 何度も再実行すると状態悪化につながる場合があるため、慎重な対応が必要です。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">NASのHDDだけ交換すれば直りますか？</h3>



<p>軽度障害なら改善するケースもありますが、RAID情報やファイルシステムまで破損している場合は、HDD交換だけでは復旧できないことがあります。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">異音やビープ音が出ています。使い続けても大丈夫ですか？</h3>



<p>異音やビープ音はHDD故障やRAID異常の警告であるケースがあります。 無理に使用を続けると状態悪化につながる可能性があるため注意が必要です。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">NASを初期化すれば直りますか？</h3>



<p>初期化によってRAID情報やファイルシステム情報が上書きされる場合があります。 重要データがある場合は、安易に初期化を行わないことをおすすめします。</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">NASの寿命はどれくらいですか？</h3>



<p>使用環境や稼働時間によって異なりますが、NASは24時間運用されることも多く、HDDは徐々に劣化していきます。 定期的なバックアップとHDD状態確認が重要です。</p>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">まとめ</h2>



<p>NASは便利な反面、RAIDや複数HDD構成によってトラブルが複雑化しやすい機器です。 特にRAID degradedやVolume crashedなどのエラーは、誤った対応によって状態が悪化するケースも少なくありません。</p>



<p>・故障HDDを安易に抜かない<br>・リビルドを繰り返さない<br>・初期化やフォーマットを行わない<br>・異音やエラーがある場合は通電を最小限にする<br>・アクセスできる場合は最優先でバックアップを行う</p>



<p>重要なデータが保存されている場合は、無理な操作を避け、慎重に対応することが大切です。</p>



<p>NASやRAIDに発生する障害は様々です。<br>その他の対処方法は下記リンクも参考にしてみてください。</p>



<ul class="wp-block-list">
<li><a target="_self" href="https://3adata.jp/blog/linkstation-6" data-type="post" data-id="2394">LinkStation（NAS）が認識しない原因と復元方法</a></li>



<li><a target="_self" href="https://3adata.jp/blog/nas-lan-disk" data-type="post" data-id="10863">アイオーデータ・LAN DISKでネットワークから共有フォルダが開けなくなったり、不具合で認識しなくなってしまった場合の対処法</a></li>



<li><a target="_self" href="https://3adata.jp/blog/landisk" data-type="post" data-id="1274">I-O DATAのランディスクが故障し起動しない場合の対処方法！</a></li>



<li><a target="_self" href="https://3adata.jp/blog/restore-data-nas" data-type="post" data-id="7748">RAID1使用LinkStationやLANDISKからデータ復旧させたい場合</a></li>



<li><a target="_self" href="https://3adata.jp/blog/nas-raid" data-type="post" data-id="10808">RAIDやNASの筐体で、データの読み込みが遅くなりデータが開けなくなる症状・原因や対処法</a></li>



<li><a target="_self" href="https://3adata.jp/blog/raid_restoration" data-type="post" data-id="6378">RAIDトラブル発生時の対処方法とデータ復旧方法</a></li>



<li><a target="_self" href="https://3adata.jp/blog/nas-failure" data-type="post" data-id="7922">赤ランプ点灯/点滅 ファームウェア更新 アクセスできない</a></li>



<li><a target="_self" href="https://3adata.jp/blog/nashdd" data-type="post" data-id="9561">ネットワーク対応のハードディスク（NAS・RAID）が突然アクセスできなくなってしまった時の故障原因・対処方法</a></li>



<li><a target="_self" href="https://3adata.jp/blog/access-failure-raid5" data-type="post" data-id="8033">【修復】NAS製品RAID5へアクセスできない場合【復旧】</a></li>



<li><a target="_self" href="https://3adata.jp/blog/nas-access-failure" data-type="post" data-id="7867">LAN接続HDDへアクセスできない障害</a></li>



<li><a target="_self" href="https://3adata.jp/blog/iodata-media" data-type="post" data-id="6846">認識しないアイオーデータ外付け製品やエラーメッセージが発生した場合</a></li>



<li><a target="_self" href="https://3adata.jp/blog/raiderror" data-type="post" data-id="9896">RAID崩壊によりデータが見れなくなったり共有フォルダ・ファイルにアクセスできなくなる故障原因と対処法</a></li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RAID崩壊・起動しないなどの障害時にやってはいけない事と対処方法</title>
		<link>https://3adata.jp/blog/raidcollapse</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Fri, 19 Aug 2022 04:06:26 +0000</pubDate>
				<category><![CDATA[3Aデータ復旧スタッフブログ]]></category>
		<category><![CDATA[LinkStation]]></category>
		<category><![CDATA[NAS]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[アクセスできない]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11941</guid>

					<description><![CDATA[RAIDは複数台のHDD（ハードディスク）やSSD（ソリッドステートドライブ）を一台のメディアとして認識される技術です。 メリットとしてストライピング以外のRAID構成ならHDDにトラブルがあった場合にでも比較的簡単に復 [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p><a target="_self" href="https://3adata.jp/blog/raidpage">RAIDは</a>複数台のHDD（<a target="_self" href="https://3adata.jp/glossarys/harddiskdrive">ハードディスク</a>）や<a target="_self" href="https://3adata.jp/glossarys/ssd">SSD</a>（ソリッドステートドライブ）を一台のメディアとして認識される技術です。</p>



<p>メリットとして<a target="_self" href="https://3adata.jp/media/raid0">ストライピング</a>以外のRAID構成ならHDDにトラブルがあった場合にでも比較的簡単に復元する事が可能になり、データを分散して転送する事が出来るので大容量のデータなどは転送速度が速くなり、業種によってはとても魅力的な技術となっています。</p>



<p><strong><span class="marker-under-red">しかし単体のHDDやSSDと違い、メディアにトラブルが発生した場合に対処するのが難しく、対処方法を間違えてしまうと復旧可能だったデータでさえ取り出す事が不可能になってしまう事があります。</span></strong></p>



<div class="wp-block-cocoon-blocks-icon-box common-icon-box block-box information-box">
<p><strong>RAID崩壊しているとエラーが表示される、共有フォルダが無くなった、データへのアクセスが困難になった場合の取り扱いには十分注意してください。障害発生後の通電や誤使用によりデータが破損し、復旧が困難になるご相談が増加しています。</strong></p>
</div>



<div class="wp-block-vk-blocks-border-box vk_borderBox vk_borderBox-background-transparent is-style-vk_borderBox-style-solid-kado-tit-tab"><div class="vk_borderBox_title_container"><i class=""></i><h4 class="vk_borderBox_title">このページはこんな人におすすめです。</h4></div><div class="vk_borderBox_body">
<ul class="is-style-vk-check-square-mark wp-block-list">
<li>RAIDにアクセスできない。</li>



<li>共有フォルダ・データが消えた。</li>



<li>ランプが点滅を繰り返している。</li>



<li>保存しているデータを取り出したい。</li>
</ul>
</div></div>



<h2 class="wp-block-heading" id="1">RAID崩壊とは？</h2>



<p>RAID構成が崩れてしまい、正しく認識しない場合をRAID崩壊と言い、具体的には下記の状態が考えられます。</p>



<p><span class="red">・管理画面でRAID崩壊・エラーなどと表示されている。<br>・マウントできません、構成が崩壊しています。と表示される。<br>・共有フォルダにアクセスできない、データが見れない。<br>・保存していたデータが壊れている、消失している。<br>・アクセスランプなどがいつもと違う点滅を繰り返している。</span></p>



<p>などがあります。</p>



<p>また下記動画の様に、異音（カリカリ、カタカタなど）電子音（ピーピー、プープー）などの音が聞こえている場合の通電は大変危険です。</p>


<iframe width="100%" height="350" src="https://www.youtube.com/embed/2ThUqAz7UW8" frameborder="0" allow="autoplay; encrypted-media" allowfullscreen></iframe>

<iframe width="100%" height="350" src="https://www.youtube.com/embed/F6Q-68cofhI" frameborder="0" allow="autoplay; encrypted-media" allowfullscreen></iframe>

<iframe width="100%" height="350" src="https://www.youtube.com/embed/G7AirLOgCQs" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe>



<p>この場合にはRAID崩壊を起こしている可能性が非常に高く、直ちに通電を辞めてください。</p>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading" id="2">RAID崩壊時してはいけない事とは</h2>



<h3 class="wp-block-heading">リビルドや再構築</h3>



<p>エラーなどが発生している場合の<a target="_self" href="https://3adata.jp/glossarys/rebuild">リビルド</a>や再構築は高確率で失敗の可能性があり、保存しているデータの破損などにつながる可能性があります。</p>



<p>本来リビルドはHDD内部のデータを再構成する作業となっており、リビルドがしっかりと完了した場合はRAIDに再びアクセスすることが可能になる事がありますが、エラーや機器の故障によりリビルドが正常に終了しない場合などには、データや構成がバラバラになってしまい状態の悪化、最悪の場合には保存していたデータが破損してしまい、データの救出が行えたとしても破損した状態でデータが検出されてしまいます。</p>



<p>RAID製品を購入して稼働させる場合のほどんどが同時期に製造されたハードディスクを利用しての稼働になる場合が多く、その場合HDDの故障時期は同時期になる場合が多くなっています。</p>



<p>使用しているHDD達に問題がある場合、リビルドを行おうとしても挿入しているハードディスクが複数問題が起こっている時には当然正常にリビルドを行うことができません。</p>



<p>リビルドが失敗してしまうと、元々書き込まなければならなかったデータが違うデータに上書きされてしまったりなどのトラブルが発生し正常にリビルドが行えなくなってしまいます。</p>



<p><span class="red">RAID製品でトラブルが起こった場合に一番危険なのはリビルドを行ってしまう事です。</span></p>



<h3 class="wp-block-heading">HDDの順番の入れ替え</h3>



<p>製品の種類によっては自動的にリビルドがかかり、失敗してしまうと保存データの破損につながります。</p>



<p>RAIDとは複数台のメディアを一台のメディアとして認識させる技術で、データ構成に従いデータを分散させて保存することができます。<br>大容量のデータなどを分散して保存することができるため、大きいデータを扱う際に非常に便利ではありますが、HDDの入れ替えを行うことによりデータ構成が読み取れなくなり保存データの閲覧が不可能になってしまう事があります。</p>



<p>また、製品によってはメディアの入れ替えを行うと自動でリビルドや<a target="_self" href="https://3adata.jp/glossarys/format">フォーマット</a>を行うものもあり、安易にハードディスクを交換してしまうと、保存データの消失につながる可能性があります。</p>



<h3 class="wp-block-heading">HDDの取り外しや単体で電源をON</h3>



<p><span class="red">状態が悪化してしまう可能性もあり、HDD単体でパソコンに接続は危険です。</span></p>



<p>RAIDによっては管理画面上などで何番のハードディスクに異常がありますなど警告が表示される場合がありますが、HDDやSSDを取り外しを行いパソコンに直接接続してもフォーマット形式が違う為アクセスはできません。</p>



<p>フォーマットしますか？などのエラーが表示された場合に誤ってフォーマットしてしまったなどの相談をお受けする事も多く、フォーマットを行ってしまった場合、復旧率は大幅に下がってしまいます。</p>



<h3 class="wp-block-heading">電源のON/OFFの繰り返し</h3>



<p>RAIDが認識しなくなってしまったり、アクセスできなくなってしまった場合、再起動する事でもとに戻るのではないか？と思ってしまいがちですが、しかしハードディスクに異常がある場合は再起動でもとに戻る事はありません。<br>HDDやSSDにエラーがある場合に通電を繰り返してしまうと保存しているデータが破損してしまったり、最悪メディアの破損が発生してしまい、保存していた大切なデータを二度と取り出す事が出来なくなってしまうでしょう。</p>



<p>RAIDに異常が発生したい場合はどは通電をせずそのまま保管して対処するのが適切です。</p>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading" id="3">RAID障害時に復旧させる方法とは？</h2>



<p>基本的にRAID崩壊を起こしている場合は専門業者に調査依頼を行った方がいいでしょう。<br>RAIDの復旧は素人レベルでは解決できない事が多く、データ消失のリスクも大きいです。</p>



<p>誤ってデータを削除してしまった場合などはフリーソフトや、市販されているソフトで復旧が可能な場合がありますが、それでもやはりリスクはあります。<br>誤操作などでデータの上書きや更なる事態の悪化につながる可能性もあり、データが重要であれば失敗したでは済まないでしょう。</p>



<p><span class="red">仕事の重要データや家族の思い出のデータが保存されていて、自分での作業に不安がある場合は、まず専門業者にご相談ください。</span></p>


<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading">弊社でご依頼が多いRAID一覧</h2>



<p>RAID崩壊を起こしている、アクセスできなくなったRAIDからデータ復旧が可能だった成功事例とその他の事例をメーカー、型番毎に紹介していますのでお困りの方はご参考にどうぞ。<br><span class="red">※リンク先は一部の成功事例を紹介させていただいております。</span></p>


<div class="newbox">

<h3>バッファロー社製のRAID構成可能メディア</h3>

<details>
  <summary>バッファロー（BUFFALO）</summary>
  <div class="details_content">
    <a target="_self" href="https://3adata.jp/success/success-case-184">HD-W500IU2/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-183">HD-W2.0TIU2/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-165">TS-I4.0TGL/R5/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-152">LS-WH2.0TGL/R1/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-148">LS420D0602/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-116">CS-WV2.0/R1/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-134">LS-W2.0TGL/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-121">TS-RH4.0TGL/R5/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-106">LS-WV2.0TL/R1/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-94">HD-WL2TU3/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-89">TS-H1.0TGL/R5/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-83">LS-WH2.0TGL/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-59">TS-WX2.0TL/R1/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-53">TS-WX1.0TL/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-36">LS-WV2.0TL/RF/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-31">LS-WV2.0TL/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-30">LS-WSX1.0L/R1WHJ/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-29">LS-W1.5TGL/R1/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-28">LS-Q2.0TL/R5/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-27">HD-W1.0TIU2/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-26">TS-H2.0TGL/R5/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-25">LS-WX4.0TL/R1J/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-56">TS-WVH2.0TL/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-21">CS-WV4.0/R1/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-14">LS-QV2.0TL/1D/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-293">LS-WX8.0TL/R1J</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-292">LS-WX6.0TL/R1J</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-291">LS-WX2.0TL/R1J</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-290">LS-WX1.0TL/R1J</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-289">LS-WX6.0TL/R1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-288">LS-WX4.0TL/R1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-287">LS-WX3.0TL/R1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-286">LS-WX2.0TL/R1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-285">LS-WX1.0TL/R1</a>
  </div>
</details>

<h3>アイ・オー・データ社製のRAID構成可能メディア</h3>

<details>

  <summary>アイオーデータ（IODATA）</summary>
  <div class="details_content">
    <a target="_self" href="https://3adata.jp/success/success-case-365">HDC-EU1.0K</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-364">HDL2-AH4.0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-202">HDS2-UTX6</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-164">HDL2-AH6.0/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-139">HDL-XV8W/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-124">HDL-XV4W/RAID6</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-144">HD-QL8TU3/R5J/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-112">HDL2-S2.0/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-98">HDL-GT4.0/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-91">HDL2-G2.0/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case">HDL-GW500U/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-55">HDL-XR4.0/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-54">HDL-XR2.0/RAID6</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-34">HDL2-A4.0/E/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-33">HDL2-A4.0/RAID0</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-32">HDL-GTR4.0/RAID5</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-24">HDL2-G1.0/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-57">HDS2-UT6.0/RAID1</a>/
    <a target="_self" href="https://3adata.jp/success/success-case-5">HDL2-S4.0/RAID1</a>
  </div>
</details>

</div>

<div class="tel-bt"><a target="_self" href="https://3adata.jp/success">その他事例はこちら</a></div>





<div class="cta-diagnosis">
  <div class="cta-diagnosis__inner">
    <p class="cta-diagnosis__eyebrow">かんたん無料</p>
    <h3 class="cta-diagnosis__title">
      3クリックで<br>
      Web診断してみる
    </h3>

    <p class="cta-diagnosis__desc">
      機器と症状を選ぶだけで、<br>
      対応可否・費用感の目安が分かります。
    </p>

    <ul class="cta-diagnosis__points">
      <li>たったの3クリックで入力不要</li>
    </ul>

    <a target="_self" href="https://3adata.jp/easypage?utm_source=Mediumad&utm_medium=Mediumbanner&utm_campaign=Medium_banner" class="cta-diagnosis__btn">
      無料で診断をはじめる
    </a>
  </div>
</div>




<h2 class="wp-block-heading" id="4">RAIDトラブル関連リンク</h2>


<h3>RAID関連のトラブルや対処方法</h3>

<div class="postlink">
<ul>
	<li><a target="_self" href="https://3adata.jp/blog/raid">RAIDは良い？悪い？RAIDを使用するメリット・デメリット</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-summary2">【RAID】認識しない・接続できない・レイド崩壊を起こしてしまった場合の復旧、復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-12">【復元】リンクステーションが赤ランプ点滅（E14エラー）時の対処法【RAID】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid0-2">RAID0からデータ復旧を行う場合の注意点と復元方法【ストライピング】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-failure">RAID障害時、注意すべき4つのポイント</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid1-2">RAID1（ミラーリング）設定の外付けHDDが故障した場合の対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-6">【対処方法】RAID1のLinkStationがエラーランプが点滅し、アクセスできなくなった【リビルド】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0（ストライピング）がRAID崩壊を起こした場合のデータ復旧</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid5-4">【復元】RAID5アレイにディスク障害が発生した場合の復旧方法【修復】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid_trouble">【RAID崩壊】RAID製品でよくあるトラブルからのデータ復旧方法【アクセス不可】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-2">RAID0、RAID1、RAID5、RAID6がRAID崩壊しアクセスできない場合の復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid1-4">ミラーリング（RAID1）仕様データ復元方法は簡単！？</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-4">RAID1のLinkStationが認識しない、アクセスできない状態になってしまった場合の対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid1-3">【復元】RAID1接続できない 3つのポイントで解決【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid5-2">【復元】RAID5サーバーが起動しない…RAID崩壊してるかも…そんな時の対処法【修復】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid5-3">RAID5仕様のNASが起動しなくなった場合の復旧・復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-10">【復元】RAID認識しないエラーは修復ソフトでデータが戻る【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-11">LAN接続HDDミラーリング RAID崩壊時の対処と修復</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-13">【復旧】RAID製品の熱暴走、落雷などの停電による障害【復元】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid1-5">ミラーリング（RAID1）データへアクセスできない場合の復旧方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid_restoration">RAIDトラブル発生時の対処方法とデータ復旧方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-3">ネットワーク接続HDD（RAID構成）認識しなくなった場合の復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-5">RAID0のLinkStationがエラーランプ点灯しアクセスできない【データ復旧 対処】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-7">【データ復元】RAID1（ミラーリング）LinkStation、LANDISKの接続エラー時の対応策【データ復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-8">RAID崩壊しアクセス不能なLinkStation、LANDISKのデータ復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/raid-summary">各RAID（レイド）レベルの長所短所を確認</a></li>
</ul>
</div>




<h2 class="wp-block-heading" id="cta">無料で診断・調査してみる</h2>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Synology シノロジー / DiskStation DS218j</title>
		<link>https://3adata.jp/success/success-case-449</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 02:08:06 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID1]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[Synology]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11087</guid>

					<description><![CDATA[メーカー Synology シノロジー 型番 DiskStation DS218j 他社診断 なし 症状/障害 RAID崩壊が発生し、パソコン・ネットワークからのアクセスが出来ず認識しない症状 診断 物理障害 結果 ミラ [&#8230;]]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-table success-table"><table class="has-fixed-layout"><tbody><tr><th>メーカー</th><td>Synology シノロジー</td></tr><tr><th>型番</th><td>DiskStation DS218j</td></tr><tr><th>他社診断</th><td>なし</td></tr><tr><th>症状/障害</th><td><a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状</td></tr><tr><th>診断</th><td>物理障害</td></tr><tr><th>結果</th><td><a target="_self" href="https://3adata.jp/blog/raid-11">ミラーリング</a>（<a target="_self" href="https://3adata.jp/blog/restore-data-nas">RAID1</a>）での使用をされており、<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>で通電時にエラーが発生してアクセスが出来ない状態となっておりました。ミラーリング内蔵ハードディスク内データの解析を進めましたが2台共に<span class="red">動作不良をご確認し物理障害にて復旧作業を実施</span>。1台からのデータ検出に成功し<span class="red">無事取り出し復旧を行っております</span>。</td></tr><tr><th>復旧容量</th><td>886GB</td></tr><tr><th>報告日数</th><td>3日</td></tr><tr><th>復旧費用</th><td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">担当スタッフからのコメント</h3>



<p>RAIDやNASのハードディスクにアクセスが出来なくなってしまってもデータ復旧は可能です。<a target="_self" href="https://3adata.jp/blog/restore-data-nas">RAID1</a>でのご使用の場合、1台のハードディスクからデータのサルベージが可能な状態が多く1台が<a target="_self" href="https://3adata.jp/blog/raid-rebuild">物理障害</a>でももう一台から論理障害として復旧させて頂く事も可能となります。症状は、ご依頼時に詳しくご診断をさせて頂きますがそのほとんどが復旧可能な状態となりますので、お気軽にご相談いただければ幸いです。NASのハードディスクでは、パソコンでの直接の取り出しが困難なことから、状態の悪化を防ぐため通電を行う際は十分にご注意いただき、ご自身での復旧はなさらないようお願い致します。</p>


<h3>エラー関連リンク</h3>

<div class="postlink">
<ul>
	<li><a target="_self" href="https://3adata.jp/blog/summary-of-common-hdd-errors">外付けHDDでよくあるエラーと原因・対処まとめ【完全ガイド】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-16">【データ復元】突然「フォーマットする必要があります」とエラーが…なぜ発生するのか、その対処方法とは？【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-15">ドライブやフォルダ、ファイルへのアクセス拒否される原因と対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-20">指定されたファイルが見つかりません。とエラーが表示された場合の復旧や対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-11">「パラメーターが間違っています。」エラー表示された外付けHDDのデータ復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-14">【対処法】I/Oデバイスエラーが起こる原因【データ復元】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/%EF%BD%83%EF%BD%92%EF%BD%83">【HDD】巡回冗長検査CRCエラーが出たメディアからの修復作業【USBメモリ】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/errormessage-2">USBデバイスが認識されませんとエラーが発生してデータにアクセスできない場合は</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-trouble">”ハードディスクの問題が検出されました”と表示された場合どのように対処すればいいのか</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-7">【ブルースクリーン】青い画面が出たパソコンを簡単に起動させる方法【ブルーバック】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/macos_errormessage">MacOSで表示されるエラーメッセージ一覧</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-16">【復元】外付けハードディスクから異音がする場合の確認方法【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/harddisk-noise">【動画あり】ハードディスクから異音やビープ音 認識しない原因</a></li>
</ul>
</div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>QNAP キューナップ / TS-231P2-4G</title>
		<link>https://3adata.jp/success/success-case-446</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Fri, 18 Oct 2019 08:28:23 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[QNAP]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID0]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11067</guid>

					<description><![CDATA[弊社では、各種<a href="https://3adata.jp/glossarys/redundantarraysofinexpensivedisks">RAID</a>筐体、構成にて復旧を行っております。ハードディスクから<span class="red">カチンカチンと異音が発生して</span>データにアクセスできなくなっている状態でもデータ復旧が可能です。RAID0の場合、内蔵されているすべてのHDDが正常に動作しないと認識が難しい為、ご依頼いただくケースの中でも多いのですが、復旧事例多数ございますのでご安心してご依頼いただければと思います。ご自身での<a href="https://3adata.jp/blog/raid-rebuild">リビルド</a>や<a href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>でのご相談、データがお取り出しできる状態かどうか<span class="red">無料でご診断いたしますのでお気軽にご相談くださいませ</span>。]]></description>
										<content:encoded><![CDATA[<table class="success-table">
<tbody>
<tr class="t1">
<th class="abo">メーカー</th>
<td>QNAP キューナップ</td>
</tr>
<tr class="t1">
<th class="abo">型番</th>
<td>TS-231P2-4G</td>
</tr>
<tr class="t2">
<th class="abo">他社診断</th>
<td>なし</td>
</tr>
<tr class="t1">
<th class="abo">症状/障害</th>
<td>
<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状
</td>
</tr>
<tr class="t2">
<th class="abo">診断</th>
<td>物理障害</td>
</tr>
<tr class="t1">
<th class="abo">結果</th>
<td>
<a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0</a>にてご使用されていた筐体でハードディスク1台から<a target="_self" href="https://3adata.jp/blog/nas-7">異音が発生</a>し動作不良にて<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>を起している状態でした。動作不良の出ているハードディスクでの調査を行い<a target="_self" href="https://3adata.jp/glossarys/physicaldamage">物理障害</a>として解析を進めさせて頂き、データの取り出しが行える状態にて<span class="red">復旧に至っております</span>。
</td>
</tr>
<tr class="t2">
<th class="abo">復旧容量</th>
<td>860GB</td>
</tr>
<tr class="t1">
<th class="abo">報告日数</th>
<td>7日</td>
</tr>
<tr class="t2">
<th class="abo">復旧費用</th>
<td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Synology シノロジー / DiskStation DS718+</title>
		<link>https://3adata.jp/success/success-case-445</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Fri, 18 Oct 2019 01:52:58 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID1]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[Synology]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11064</guid>

					<description><![CDATA[メーカー Synology シノロジー 型番 DiskStation DS718+ 他社診断 なし 症状/障害 RAID崩壊が発生し、パソコン・ネットワークからのアクセスが出来ず認識しない症状 診断 物理障害 結果 RA [&#8230;]]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-table success-table"><table class="has-fixed-layout"><tbody><tr><th>メーカー</th><td>Synology シノロジー</td></tr><tr><th>型番</th><td>DiskStation DS718+</td></tr><tr><th>他社診断</th><td>なし</td></tr><tr><th>症状/障害</th><td><a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状</td></tr><tr><th>診断</th><td>物理障害</td></tr><tr><th>結果</th><td><a target="_self" href="https://3adata.jp/blog/raid1-5">RAID1</a>にてご使用されていた<a target="_self" href="https://3adata.jp/glossarys/harddiskdrive">ハードディスク</a>からのデータ復旧にて調査を行いました。ハードディスクは<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し<span class="red">アクセスが困難な状態</span>となっており、2台のハードディスクを個別解析にてデータ取り出し可能な状態に調整後データ差分を計測し復旧のご案内を行っております。2台のハードディスク共に<span class="red">動作不良</span>にて読み込めない部分が点在し、各ハードディスクからデータの取り出しを行い<span class="red">復旧させて頂きました</span>。</td></tr><tr><th>復旧容量</th><td>2.22TB</td></tr><tr><th>報告日数</th><td>8日</td></tr><tr><th>復旧費用</th><td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">担当スタッフからのコメント</h3>



<p><a target="_self" href="https://3adata.jp/blog/nashdd">RAID</a>やNASの筐体でアクセスが出来なくなっていたり、<a target="_self" href="https://3adata.jp/blog/hddformaterror">エラーメッセージ</a>が表示されてデータの取り出しが困難な状態でもデータ復旧は可能です。ご使用されているRAIDやNASが不調だと感じたらまずは一度ご相談くださいませ。よくあるケースでは<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>にてアクセスできなくなった状態でリビルドをご自身で実施してデータが消えてしまったり、全く認識しなくなるなど症状が悪化してからのご相談を頂きますが、ご自身で復旧を試みる前にご相談いただければ、まずはデータが取り出し可能な状態かどうかを無料でご診断いたします。単体のNASや複数台構成のRAIDでもお受付しておりますのでお気軽にご相談くださいませ。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ASUSTOR アサスター / AS1002T</title>
		<link>https://3adata.jp/success/success-case-444</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Thu, 17 Oct 2019 02:25:30 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[ASUSTOR]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID0]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11061</guid>

					<description><![CDATA[メーカー ASUSTOR アサスター 型番 AS1002T 他社診断 なし 症状/障害 RAID崩壊が発生し、パソコン・ネットワークからのアクセスが出来ず認識しない症状 診断 物理障害 結果 大容量ストレージのNASにて [&#8230;]]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-table success-table"><table class="has-fixed-layout"><tbody><tr><th>メーカー</th><td>ASUSTOR アサスター</td></tr><tr><th>型番</th><td>AS1002T</td></tr><tr><th>他社診断</th><td>なし</td></tr><tr><th>症状/障害</th><td><a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状</td></tr><tr><th>診断</th><td>物理障害</td></tr><tr><th>結果</th><td>大容量ストレージの<a target="_self" href="https://3adata.jp/glossarys/networkattachedstorage">NAS</a>にて<a target="_self" href="https://3adata.jp/blog/raid-15">RAID崩壊</a>が発生し、<span class="red">ネットワークからアクセスが出来ない状態</span>となっておりました。内蔵HDD2台のうち1台が通電認識が行えない<a target="_self" href="https://3adata.jp/blog/raid-rebuild">物理障害</a>となっており、調査・解析を進めてご案内しております。RAID構成は「<a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0</a>」でご使用されており内蔵HDD2台からのデータ抽出を行い<span class="red">復旧しております</span>。</td></tr><tr><th>復旧容量</th><td>4TB</td></tr><tr><th>報告日数</th><td>16日</td></tr><tr><th>復旧費用</th><td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">担当スタッフからのコメント</h3>



<p>弊社では、ご使用されている<strong>NAS・RAID</strong>の構成が分からなくなっていても調査をさせて頂いております。特に4台以上の内蔵HDDを搭載した筐体では、<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>でのご依頼を多数いただいており、その中でも使用していた<a target="_self" href="https://3adata.jp/blog/nas-raid">RAID</a>の構成が分からない状態でのご依頼がほとんどです。RAIDの構成やデータの復旧での調査解析を進め、ご案内させていただきます。<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>や<a target="_self" href="https://3adata.jp/blog/raid-rebuild">リビルド</a>の失敗でデータにアクセスが出来なくなってしまったらお気軽にご相談くださいませ。</p>


<h3>エラー関連リンク</h3>

<div class="postlink">
<ul>
	<li><a target="_self" href="https://3adata.jp/blog/summary-of-common-hdd-errors">外付けHDDでよくあるエラーと原因・対処まとめ【完全ガイド】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-16">【データ復元】突然「フォーマットする必要があります」とエラーが…なぜ発生するのか、その対処方法とは？【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-15">ドライブやフォルダ、ファイルへのアクセス拒否される原因と対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-20">指定されたファイルが見つかりません。とエラーが表示された場合の復旧や対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-11">「パラメーターが間違っています。」エラー表示された外付けHDDのデータ復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-14">【対処法】I/Oデバイスエラーが起こる原因【データ復元】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/%EF%BD%83%EF%BD%92%EF%BD%83">【HDD】巡回冗長検査CRCエラーが出たメディアからの修復作業【USBメモリ】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/errormessage-2">USBデバイスが認識されませんとエラーが発生してデータにアクセスできない場合は</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-trouble">”ハードディスクの問題が検出されました”と表示された場合どのように対処すればいいのか</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-7">【ブルースクリーン】青い画面が出たパソコンを簡単に起動させる方法【ブルーバック】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/macos_errormessage">MacOSで表示されるエラーメッセージ一覧</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-16">【復元】外付けハードディスクから異音がする場合の確認方法【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/harddisk-noise">【動画あり】ハードディスクから異音やビープ音 認識しない原因</a></li>
</ul>
</div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NETGEAR ネットギア / ReadyNAS 214 RN21400-100AJS</title>
		<link>https://3adata.jp/success/success-case-443</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Mon, 07 Oct 2019 04:05:26 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[NETGEAR]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID0]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11031</guid>

					<description><![CDATA[<a href="https://3adata.jp/blog/raid0-3">RAID0</a>の場合、1台でもハードディスクに不具合が出てしまうと読み出しや書き込み、アクセスが行えない状態となります。<a href="https://3adata.jp/blog/nas-raid">異音が発生</a>していたり、アクセスが出来なくなった場合は通電をお控え頂きご相談くださいませ。NASやRAIDの筐体の調査、ハードディスクの調査を行いデータの取り出しが行えるかどうかのご診断を行い、お見積り致します。また、<span class="red">ご使用中のRAIDがどの構成で使用しているかわからない場合</span>でも、弊社で調査を行いご案内いたしますので、お気軽にご相談くださいませ。<a href="https://3adata.jp/blog/raid-rebuild">RAID</a>や<a href="https://3adata.jp/blog/nashdd">NAS</a>のハードディスクが<a href="https://3adata.jp/glossarys/physicaldamage">物理障害</a>であってもデータ復旧可能です。]]></description>
										<content:encoded><![CDATA[<table class="success-table">
<tbody>
<tr class="t1">
<th class="abo">メーカー</th>
<td>NETGEAR ネットギア</td>
</tr>
<tr class="t1">
<th class="abo">型番</th>
<td>ReadyNAS 214 RN21400-100AJS</td>
</tr>
<tr class="t2">
<th class="abo">他社診断</th>
<td>なし</td>
</tr>
<tr class="t1">
<th class="abo">症状/障害</th>
<td>
<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状
</td>
</tr>
<tr class="t2">
<th class="abo">診断</th>
<td>物理障害</td>
</tr>
<tr class="t1">
<th class="abo">結果</th>
<td>
<a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0</a>でご使用されていた筐体で、1台から<a target="_self" href="https://3adata.jp/blog/nas-raid">異音が発生</a>し<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>のエラーが出ている症状でした。1台のハードディスクは正常動作が確認でき、不具合を起しているハードディスクでの復旧作業を実施してご案内しております。作業後無事に正常動作に至り、<span class="red">仮想RAID</span>をお組みして<span class="red">データの取り出しを行い復旧しております</span>。
</td>
</tr>
<tr class="t2">
<th class="abo">復旧容量</th>
<td>1.13TB</td>
</tr>
<tr class="t1">
<th class="abo">報告日数</th>
<td>14日</td>
</tr>
<tr class="t2">
<th class="abo">復旧費用</th>
<td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NETGEAR ネットギア / ReadyNAS 424 RN42400-100AJS</title>
		<link>https://3adata.jp/success/success-case-442</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Sat, 05 Oct 2019 01:45:58 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[NETGEAR]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID6]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=11026</guid>

					<description><![CDATA[メーカー NETGEAR ネットギア 型番 ReadyNAS 424 RN42400-100AJS 他社診断 なし 症状/障害 RAID崩壊が発生し、パソコン・ネットワークからのアクセスが出来ず認識しない症状 診断 物理 [&#8230;]]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-table success-table"><table class="has-fixed-layout"><tbody><tr><th>メーカー</th><td>NETGEAR ネットギア</td></tr><tr><th>型番</th><td>ReadyNAS 424 RN42400-100AJS</td></tr><tr><th>他社診断</th><td>なし</td></tr><tr><th>症状/障害</th><td><a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状</td></tr><tr><th>診断</th><td>物理障害</td></tr><tr><th>結果</th><td>RAID筐体は<strong>RAID 0/1/5/6/10(1+0)/X-RAID2/Flex-RAID</strong>　と様々な<span class="red">RAID構成</span>に対応した製品で、どの構成で使用していたか不明な状態から調査を開始いたしました。4台内蔵できる筐体からRAID6やRAID10(1+0)でご使用されている方が多く、こちらのご使用もRAID6と判明し解析を実施。筐体内ハードディスク1台が異音による<a target="_self" href="https://3adata.jp/glossarys/physicaldamage">物理障害</a>を発生している状態でしたが無事に復旧しております。</td></tr><tr><th>復旧容量</th><td>4.44TB</td></tr><tr><th>報告日数</th><td>18日</td></tr><tr><th>復旧費用</th><td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">担当スタッフからのコメント</h3>



<p><a target="_self" href="https://3adata.jp/glossarys/redundantarraysofinexpensivedisks">RAID</a>の構成や、ご使用されていた環境がご不明であっても復旧させて頂いております。特にRAIDの場合、<strong>4台以上内蔵している筐体</strong>では「RAID 0/1/5/6/10(1+0)」と多様な使用方法があり、ご購入時に設定して頂くのでご自身でお判りになられないケースも多く、弊社ではRAIDの構成自体の調査も執り行っております。自動バックアップや不具合時にご対処頂きやすいRAID6やRAID10(1+0)のご使用が最も多く、大容量で使用されている方はRAID0でのご依頼が多数ございます。ネットワークからのアクセスが出来なくなったり、RAID崩壊、物理的障害に遭われたらまずご相談くださいませ。</p>


<h3>エラー関連リンク</h3>

<div class="postlink">
<ul>
	<li><a target="_self" href="https://3adata.jp/blog/summary-of-common-hdd-errors">外付けHDDでよくあるエラーと原因・対処まとめ【完全ガイド】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-16">【データ復元】突然「フォーマットする必要があります」とエラーが…なぜ発生するのか、その対処方法とは？【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-15">ドライブやフォルダ、ファイルへのアクセス拒否される原因と対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-20">指定されたファイルが見つかりません。とエラーが表示された場合の復旧や対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-11">「パラメーターが間違っています。」エラー表示された外付けHDDのデータ復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-14">【対処法】I/Oデバイスエラーが起こる原因【データ復元】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/%EF%BD%83%EF%BD%92%EF%BD%83">【HDD】巡回冗長検査CRCエラーが出たメディアからの修復作業【USBメモリ】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/errormessage-2">USBデバイスが認識されませんとエラーが発生してデータにアクセスできない場合は</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-trouble">”ハードディスクの問題が検出されました”と表示された場合どのように対処すればいいのか</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-7">【ブルースクリーン】青い画面が出たパソコンを簡単に起動させる方法【ブルーバック】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/macos_errormessage">MacOSで表示されるエラーメッセージ一覧</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-16">【復元】外付けハードディスクから異音がする場合の確認方法【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/harddisk-noise">【動画あり】ハードディスクから異音やビープ音 認識しない原因</a></li>
</ul>
</div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>シノロジー Synology / DiskStation DS218j</title>
		<link>https://3adata.jp/success/success-case-441</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Sat, 07 Sep 2019 07:46:17 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID0]]></category>
		<category><![CDATA[RAID崩壊]]></category>
		<category><![CDATA[Synology]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=10994</guid>

					<description><![CDATA[メーカー シノロジー Synology 型番 DiskStation DS218j 他社診断 なし 症状/障害 RAID崩壊が発生し、パソコン・ネットワークからのアクセスが出来ず認識しない症状 診断 物理障害 結果 RA [&#8230;]]]></description>
										<content:encoded><![CDATA[
<figure class="wp-block-table success-table"><table class="has-fixed-layout"><tbody><tr><th>メーカー</th><td>シノロジー Synology</td></tr><tr><th>型番</th><td>DiskStation DS218j</td></tr><tr><th>他社診断</th><td>なし</td></tr><tr><th>症状/障害</th><td><a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状</td></tr><tr><th>診断</th><td>物理障害</td></tr><tr><th>結果</th><td><a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0</a>でご使用のHDDが、パソコンからのアクセスができず<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>とエラーが出てしまっておりました。ハードディスク本体が動作不良を起しており、物理障害でのご対応を行っております。異音などは無い物の、動作が重く不良セクタによる障害が発生しており、<span class="red">ディスクイメージ</span>を作成しての解析にて<span class="red">無事に復旧しております</span>。</td></tr><tr><th>復旧容量</th><td>963GB</td></tr><tr><th>報告日数</th><td>14日</td></tr><tr><th>復旧費用</th><td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">担当スタッフからのコメント</h3>



<p>弊社では、<a target="_self" href="https://3adata.jp/blog/raid_trouble">RAID</a>筐体各種復旧を行っております。特に<a target="_self" href="https://3adata.jp/blog/raid-15">RAID崩壊</a>による不具合でのご依頼が多く、ご自身での復旧が困難なことから、データを諦めてしまう方もいらっしゃいますが、RAID崩壊での復旧はほとんどがデータ自体は残っており復旧が可能です。お使いのRAID筐体での不具合発生時は、一度弊社データ復旧サービスへご相談ください。まずは、データの取り出しが行えるかどうかの調査を無料で執り行います。<a target="_self" href="https://3adata.jp/blog/raid0-3">RAID0</a>や<a target="_self" href="https://3adata.jp/blog/%e3%80%90%e3%83%87%e3%83%bc%e3%82%bf%e5%be%a9%e5%85%83%e3%80%91raid1%e3%81%ae%e5%86%8d%e6%a7%8b%e7%af%89%e6%96%b9%e6%b3%95%e3%81%a8%e3%81%9d%e3%81%ae%e5%8d%b1%e9%99%ba%e6%80%a7%e3%80%90%e3%83%9f">RAID1</a>といったどのような構成であってもご相談お受付いたしますので是非ご検討くださいませ。</p>


<h3>エラー関連リンク</h3>

<div class="postlink">
<ul>
	<li><a target="_self" href="https://3adata.jp/blog/summary-of-common-hdd-errors">外付けHDDでよくあるエラーと原因・対処まとめ【完全ガイド】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-16">【データ復元】突然「フォーマットする必要があります」とエラーが…なぜ発生するのか、その対処方法とは？【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-15">ドライブやフォルダ、ファイルへのアクセス拒否される原因と対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-20">指定されたファイルが見つかりません。とエラーが表示された場合の復旧や対処方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-11">「パラメーターが間違っています。」エラー表示された外付けHDDのデータ復元方法</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-14">【対処法】I/Oデバイスエラーが起こる原因【データ復元】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/%EF%BD%83%EF%BD%92%EF%BD%83">【HDD】巡回冗長検査CRCエラーが出たメディアからの修復作業【USBメモリ】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/errormessage-2">USBデバイスが認識されませんとエラーが発生してデータにアクセスできない場合は</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-trouble">”ハードディスクの問題が検出されました”と表示された場合どのように対処すればいいのか</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/symptom-7">【ブルースクリーン】青い画面が出たパソコンを簡単に起動させる方法【ブルーバック】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/macos_errormessage">MacOSで表示されるエラーメッセージ一覧</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/hdd-16">【復元】外付けハードディスクから異音がする場合の確認方法【復旧】</a></li>
	<li><a target="_self" href="https://3adata.jp/blog/harddisk-noise">【動画あり】ハードディスクから異音やビープ音 認識しない原因</a></li>
</ul>
</div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>アイオーデータ IO-DATA / LANDISK Home HDL4-G2.0</title>
		<link>https://3adata.jp/success/success-case-440</link>
		
		<dc:creator><![CDATA[技術スタッフ]]></dc:creator>
		<pubDate>Fri, 06 Sep 2019 07:54:50 +0000</pubDate>
				<category><![CDATA[成功事例]]></category>
		<category><![CDATA[成功事例（RAID各種・JBOD）]]></category>
		<category><![CDATA[成功事例（物理障害）]]></category>
		<category><![CDATA[NAS]]></category>
		<category><![CDATA[RAID]]></category>
		<category><![CDATA[RAID0]]></category>
		<category><![CDATA[物理障害]]></category>
		<guid isPermaLink="false">https://3adata.jp/?p=10991</guid>

					<description><![CDATA[<a href="https://3adata.jp/blog/raid0-3">RAID0</a>でご使用の場合、1台でもハードディスクが不具合を起してしまうと<a href="https://3adata.jp/blog/raid_trouble">RAID崩壊</a>が発生し他のHDDが正常であってもデータの取り出しが難しくなります。無理に通電し状況を悪化させないよう十分にお気をつけいただき、まずは復旧が行えるかどうかご診断させていただきます。RAIDでのご依頼は<a href="https://3adata.jp/blog/nas-raid">NAS</a>でのご使用から外付けHDDとしてご使用いただいている物まで多数復旧しております。他社では、<span class="red">復旧費用が高額なRAID製品やNAS製品でも弊社では安価にお見積り致します</span>。]]></description>
										<content:encoded><![CDATA[<table class="success-table">
<tbody>
<tr class="t1">
<th class="abo">メーカー</th>
<td>アイオーデータ IO-DATA</td>
</tr>
<tr class="t1">
<th class="abo">型番</th>
<td>LANDISK Home HDL4-G2.0</td>
</tr>
<tr class="t2">
<th class="abo">他社診断</th>
<td>なし</td>
</tr>
<tr class="t1">
<th class="abo">症状/障害</th>
<td>
<a target="_self" href="https://3adata.jp/blog/raiderror">RAID崩壊</a>が発生し、パソコン・ネットワークからの<a target="_self" href="https://3adata.jp/blog/landisk-raid1">アクセスが出来ず認識しない</a>症状
</td>
</tr>
<tr class="t2">
<th class="abo">診断</th>
<td>物理障害</td>
</tr>
<tr class="t1">
<th class="abo">結果</th>
<td>
個人使用でパソコンからデータを移行している最中に認識しなくなり、<span class="red">データにアクセスできなくなった</span>との事で、調査したところRAID0の1台のハードディスクが起動しておらず筐体側での認識が行えない状態となっておりました。調整のみでは復旧が困難な状況から、<a target="_self" href="https://3adata.jp/glossarys/physicaldamage">物理障害</a>として基板の情報書き換え作業を実施。基板の交換作業後動作に至り、<span class="red">無事復旧しております</span>。
</td>
</tr>
<tr class="t2">
<th class="abo">復旧容量</th>
<td>460GB</td>
</tr>
<tr class="t1">
<th class="abo">報告日数</th>
<td>7日</td>
</tr>
<tr class="t2">
<th class="abo">復旧費用</th>
<td><a target="_self" href="https://3adata.jp/price">復旧費用</a>はこちら</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Disk: Enhanced  を使用したページ キャッシュ

Served from: 3adata.jp @ 2026-06-21 02:25:44 by W3 Total Cache
-->